Artificial hip joint
Before

| Tool |
Sandpaper |
|---|---|
| Problem |
Manual processing caused uneven surface. |
After

| Tool | XEBEC Brush for Surface (A21-CB25M) |
|---|---|
| Result | Fully automated polishing enabled complete removal of cutter marks and improvement of surface quality. |
Workpiece information

| Industry |
Medical |
|---|---|
| Part name |
Artificial hip joint |
| Material type |
Titanium alloy |
| Machining process |
Ball end mill processing |
Processing conditions
| Tool |
XEBEC Brush for Surface (A21-CB25M) |
|---|---|
| Details of processing |
Removal of cutter marks after ball-end milling process |
| Spindle speed (min⁻¹) |
4,000 |
| Table feed (mm/min) |
1,500 |
| Depth of cut (mm) |
0.4 |
| Machining time (sec) |
– |